ADM1075
ADM1075 ALERT PIN BEHAVIOR
The ADM1075 provides a very flexible alert system, whereby
one or more fault/warning conditions can be indicated to an
external device.
FAULTS AND WARNINGS
A PMBus fault on the ADM1075 is always generated due to an
analog event and causes a change in state in the hot swap output,
turning it off. The three defined fault sources are as follows:
? Undervoltage (UV) event detected on the UVH and UVL
pins
? Overvoltage (OV) event detected on the OV pin
? Overcurrent (OC) event that causes a hot swap timeout
Faults are continuously monitored, and, as long as power is
applied to the device, they cannot be disabled. When a fault
occurs, a corresponding status bit is set in one or more
STATUS_xxx registers.
A value of 1 in a status register bit field always indicates a fault
or warning condition. Fault and warning bits in the status
registers are latched when set to 1. To clear a latched bit to 0—
provided that the fault condition is no longer active—use the
CLEAR_FAULTS command or use the OPERATION command
to turn the hot swap output off and then on again.
The latched status registers provide fault recording functionality.
In the event of a fault, the HS_SHUTDOWN_CAUSE bits in
the manufacturing specific status register (0x80) can be used to
identify the fault source (UV, OV, or OC). Other status registers
can also be checked for more fault and warning information.
A warning is less severe than a fault and never causes a change
in the state of the hot swap controller. The eight sources of a
warning are defined as follows:
? CML: a communications error occurred on the I 2 C bus
? HS timer was active (HSTA): the current regulation was
active but does not necessarily shut the system down
? IOUT OC warning from the ADC
? IOUT Warning 2 from the ADC
? VIN UV warning from the ADC
? VIN OV warning from the ADC
? VAUX UV warning from the ADC
? VAUX OV warning from the ADC
? PIN OP warning from the ADC
GENERATING AN ALERT
Data Sheet
By default, at power-up, the open-drain GPOx/ALERTx
outputs are high impedance; therefore, the pins can be pulled
high through resistors. No faults or warnings are enabled on the
GPO2/ALERT2 pin at power-up; the user must explicitly enable
the faults or warnings to be monitored. The FET health bad
warning is active by default on the GPO1/ALERT1/CONV pin
at power-up.
Any one or more of the faults and warnings listed in the Faults
and Warnings section can be enabled and cause an alert, making
the corresponding GPOx/ALERTx pin active. By default, the
active state of a GPOx/ALERTx pin is low.
For example, to use GPO1/ALERT1/CONV to monitor the
IOUT OC warning from the ADC, the followings steps must be
performed:
1. Set a threshold level with the IOUT_OC_WARN_LIMIT
command.
2. Set the IOUT_OC_WARN_EN1 bit in the
ALERT1_CONFIG register
3. Start the power monitor sampling on IOUT.
If an IOUT sample is taken that is above the configured
IOUT OC value, the GPO1/ALERT1/CONV pin is taken
low, signaling an interrupt to a processor.
HANDLING/CLEARING AN ALERT
When faults/warnings are configured on the GPOx/ALERTx pins,
the pins become active to signal an interrupt to the processor.
(These pins are active low, unless inversion is enabled.) The
GPOx/ALERTx signal performs the function of an SMBAlert.
Note that the GPOx/ALERTx pins can become active indepen-
dently of each other, but they are always made inactive together.
A processor can respond to the interrupt in one of two basic ways:
? If there is only one device on the bus, the processor can
simply read the status bytes and issue a CLEAR_FAULTS
command to clear all the status bits, which causes the
deassertion of the GPOx/ALERTx line. If there is a persistent
fault—for example, an undervoltage on the input—the status
bits remain set after the CLEAR_FAULTS command is
executed because the fault has not been removed. However,
the GPOx/ALERTx line is not pulled low unless a new fault/
warning becomes active. If the cause of the SMBAlert is a
power monitor generated warning and the power monitor
A host device can periodically poll the ADM1075 using the
status commands to determine whether a fault/warning is
active. However, this polling is very inefficient in terms of
software and processor resources. The ADM1075 has two
GPOx/ALERTx output pins that can be used t o generate
interrupts to a host processor, GPO1/ALERT1/CONV and
GPO2/ALERT2.
?
Rev. C | Page 36 of 52
is running continuously, the next sample generates a new
SMBAlert after the CLEAR_FAULTS command is issued.
If there are many devices on the bus, the processor can issue
an SMBus alert response address command to find out
which device asserted the SMBAlert line. The processor
can read the status bytes from that device and issue a
CLEAR_FAULTS command.
相关PDF资料
EVAL-ADM1087EBZ BOARD EVALUATION FOR ADM1087
EVAL-ADM1166TQEBZ BOARD EVAL FOR ADM1166TQ
EVAL-ADM1168LQEBZ BOARD EVAL FOR ADM1168LQ
EVAL-ADM1170EBZ BOARD EVALUATION FOR ADM1170
EVAL-ADM1171EBZ BOARD EVALUATION FOR ADM1171
EVAL-ADM1172EBZ BOARD EVALUATION FOR ADM1172
EVAL-ADM1175EBZ BOARD EVALUATION FOR ADM1175
EVAL-ADM1176EBZ BOARD EVALUATION FOR ADM1176
相关代理商/技术参数
EVAL-ADM1075EBZ 制造商:Analog Devices 功能描述:EVAL -48V CONTROLLER ADM1075 制造商:Analog Devices 功能描述:ADM1075, HOT SWAP, 350W, EVAL BOARD
EVAL-ADM1087EB 功能描述:BOARD EVAL FOR ADM1087 RoHS:否 类别:编程器,开发系统 >> 评估演示板和套件 系列:Simple Sequencers® 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源
EVAL-ADM1087EBZ 功能描述:BOARD EVALUATION FOR ADM1087 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:Simple Sequencers® 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源
EVAL-ADM1166TQEBZ 功能描述:BOARD EVAL FOR ADM1166TQ RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:* 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
EVAL-ADM1168LQEBZ 功能描述:BOARD EVAL FOR ADM1168LQ RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:* 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
EVAL-ADM1169LQEBZ 功能描述:BOARD EVAL FOR ADM1169LQ RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:Super Sequencer® 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源
EVAL-ADM1170EBZ 功能描述:BOARD EVALUATION FOR ADM1170 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
EVAL-ADM1171EBZ 功能描述:BOARD EVALUATION FOR ADM1171 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081